FemtoViewer is a high performance near IR viewer optimized for applications involving the alignment of near-infrared Ti:Sapphire laser beams.

Titanium-doped sapphire (Ti:Sapphire) has become by far the most common laser material for the generation of ultrashort pulses. The wavelengths in which Ti:Sapphire crystal will produce gain stretch from 660nm to 1180 nm. A bandwidth of over 400 nm in the near IR region makes Ti:Sapphire a very attractive material for use in tunable laser sources and generation of very short pulses with a broad tuning range.

FemtoViewer is intended for alignment of both CW and femtosecond Ti:Sapphire lasers.
 

Write us about your femtosecond project and enter a chance to
win FemtoViewer

When writing to us please enter "Win FemtoViewer" in the subject line.

Please answer the following questions: what is your femtosecond project about?

Do you have femtosecond system now? If yes, please describe briefly, what you have and how you plan to improve it in the next 6-12 months.

Do you plan to purchase femtosecond products in the next 6 months? Yes-no
If yes, please describe briefly your requirements.

Del Mar Ventures> Product List> IR viewers>

Visit Del Mar Ventures new web site http://www.femtosecondsystems.com/ completely devoted to femtosecond products:


 

High performance infrared monocular viewers are designed to observe radiation emitted by infrared sources. They can be used to observe indirect radiation of IR LED's and diode lasers, Nd:YAG, Ti:Sapphire, Cr:Forsterite, dye lasers and other laser sources. IR viewers are ideal for applications involving the alignment of infrared laser beams and of optical components in near-infrared systems.
The light weight, compact monocular may be used as a hand-held or facemask mounted for hands free operation.

Ultraviolet viewers are designed to observe radiation emitted by UV sources.


Applications:

Laser alignment and safety
Lasers, which can be observed with IR-viewers:
GaAs laser diodes @800 - 950nm, GaAlAs @1350nm, Nd:YAG @ 1064nm,
Ti:Sapphire @ 690 - 1000nm, Li:F2 @1090 - 1270nm, Cr: Forsterite @ 1150 - 1350nm etc.
Near IR viewers are extremely important for locating stray beam reflections that may cause eye damage or injury.

related products: femtoseconds Ti:Sapphire laser kit> Nd:YAG laser frequency converters> femtosecond Cr:Forsterite laser> IR optics>

Semiconductor inspection

New Application! From Optics.Org: Infrared light probes varicose veins.
An infrared digital imaging system will be used to compare three varicose vein treatments.
 

New Application! From Optics.Org: Infrared light detects tooth decay.
A dentist’s toolkit for detecting tooth decay could soon include an infrared-imaging system.
Shining infrared light with a wavelength of 1310 nm through a tooth is an effective way to spot early decay, according to a team from the University of California at San Francisco, US.
 

Thermal imaging
The IR-viewers can be used to image the thermal radiation of objects above 600°C (such as kilns, furnaces or solder pots). Objects in this temperature range (and hotter) emit enough infrared radiation in the 0.8-1.5 micron wavelength range to be imaged.

Night vision
Invisible near-infrared illuminator is used as a light source for night vision applications.

Forensics and Art Restoration

Professional Dark Rooms

Photo-processing
Near-infrared viewing devices have become invaluable tools for assuring error-free processing of color sensitive materials in the photography

Typical Spectral Response
(sensitivity versus wavelength)

Minimum power densities required to view an infrared laser beam from a distance of one meter:
-20
mW/cm2 for 1.06mm
-500
mW/cm2 for 1.3mm

Standard IR viewers have spectral response up to 1300nm. IR viewers with extended spectral range are available: models 1700 (with sensitivity up to 1700nm) and model 2000 (with sensitivity up to 2000nm).
 

 

Specifications

Model

SM-3R

ABRIS-M

Version 1

Version 2

Photocathode,
material, diameter

S-1, 11mm
S-1+ for extended spectral range

S-1, 18mm
S-1+ for extended spectral range

Objective Lens, F (mm)

F 1,2 / 20 without iris

F1.4/26 without iris

F2/58 with iris

Magnification

1.4x

1,0x

2.5x

Field of View

30°

38°

18°

Resolution, l/mm

50

60

Working Range (Focus)

15 cm to infinity

15 cm to infinity

25 cm to infinity

Spectral Response

See table for available models

See table for available models

Battery

3 V (2 x Type LR44, CR1/3N or other compatible)

1.5V AAA type
supplied with rechargeable battery and charger

Dimensions, mm

145 x 65 x 43

175 x 75 x 55

220 x 78 x 55

Weight, g

250

380

580

 

Infrared Viewers SM-3R 2000 (SM-3R 1700)
 

IR viewers SM-3R 2000 (1700) have extended spectral response up to 2000nm (1700nm). Minimum power densities required to view an infrared laser beam from a distance of one meter using infrared viewer SM-3R 2000 are approximately as follows:
10 mW/cm2 for a 1.6 mm
50 mW/cm2 for a 1.7 mm
200 mW/cm2 for a 1.8 mm
2 - 5 W/cm2 for a 2.0 mm
 

Typical spectral curve of the SM-3R2000 in the near - infrared range

 

New! We now offer Image Intensifiers for use in IR viewer devices for OEM customers

 

Del Mar Ventures Home

Product list

Other products for IR range: IR optics - Variable Attenuator for High-Power Laser Radiation

Related products: femtoseconds Ti:Sapphire laser kit> Nd:YAG laser frequency converters>
femtosecond Cr:Forsterite laser>

 


Del Mar Ventures
4119 Twilight Ridge, San Diego, CA 92130
tel: (858) 755-6727, v/fax (858) 630-2376 femto@sciner.com