Ready made detectors based on Microchannel Plates

Fast Position- and Time-Sensitive MCP-Detectors
  
Detectors with Delay-Line Readout (DLD, UHV compatible)
   Detectors with Wedge-and-Strip-Anode (WSD, UHV compatible)
   Resistive Anode Detectors (RAD, UHV compatible)
   Electronics and UHV feedthrough

Flange mounted UHV detectors

Image Intensifiers



Detectors with Delay-Line Readout (DLD, UHV compatible)

DLD 40/2: 2-dim Delay-Line-Detector incl. 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%, Multihit proved) for Chevron configuration. Active diameter of the detector is 48mm, quality linear diameter is 44mm. Detector size: diameter 94mm, height 30mm. Maximum count rate of the anode is 1MHz.

DLD 40/3: same as DLD 40/2, but incl. 3MCP for Z-stack

DLD 40/P: 2-dim Delay-Line-Detector incl. 2 Photonis microchannel plates imaging quality (MCP 80:1, 1mm thick, 46mm outer diameter, matched in resistance within 10%, Multihit proved) for Chevron configuration. Active diameter of the detector is 44mm, quality linear diameter is 43mm. Detector size: diameter 94mm, height 30mm. Maximum count rate of the anode is 1MHz.

DLD 80/2: 2-dim Delay-Line-Detector incl. 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 86mm outer diameter, matched in resistance within 10% multi hit proved) for Chevron configuration. Active diameter of the detector is 83mm, quality linear diameter is 79mm. Detector size: diameter 144mm, height 30mm. Maximum count rate of the anode is 1MHz.

DLD 80/3: same as DLD 80/2, but incl. 3 MCP for Z-stack. Height is 30mm

DLD 100/2: 2-dim Delay-Line-Detector incl. Phillips microchannel plates (MCP Phillips 80:1, 1mm thick, 100mm outer measure, square, matched in resistance within 20%) for Chevron configuration. Active size 96mm square, quality area 93mm square. Maximum count rate of the anode is 1MHz.


Detectors with Wedge-and-Strip-Anode (WSD, UHV compatible)

WSD 40/2: 2-dim Wedge-and-Strip-Detector incl 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 48mm, quality linear diameter is 46mm. Detector size: diameter 66mm, height 7.5mm. Maximum count rate of the anode is 20kHz.

WSD 40/3: same as WSD 40/2, but incl. 3 MCP for Z-stack


Resistive Anode Detectors (RAD, UHV compatible)

RAD 40/2: 1-dim Resistive-Anode-Detector incl 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active length of the detector is 48mm, quality linear length is 40mm. Active width can be chosen between 5 and 25mm. Detector size: diameter 66mm, height 7.5mm.

RAD 40/3: same as RAD 40/2, but incl. 3 MCP. Height is 8.5mm


Electronics and UHV feedthrough

DLATR6/N: triple width NIM-module differential amplifier constant fraction-unit all 6 channels for use with any DLD. Output NIM. For custom connection to vacuum system.

DLATR6/E: triple width NIM-module differential amplifier constant fraction-unit all 6 channels for use with any DLD. Output ECL incl. integrated 2-channel ECL-TTL converter for monitoring. For custom connection to vacuum system.

CATSA2: preamplifier box incl. 2 slow high end charge integrating preamps for very good signal-to-noise ratio (200nanosec or 1microsec fall time). Amplification optimized for use with RAD 40. Achievable position resolution with RAD 40 is 100 micron.

CATSA3: preamplifier box incl. 3 slow high end charge integrating preamps for very good signal-to-noise ratio (200nanosec or 1microsec fall time). Amplification optimized for use with WSD 40. Achievable position resolution with WSD 40 is 50 micron.

 

HM1: 4-channel histogramming TDC with 32MB memory on board for 0.5-1 MHz data acquisition rate, 130ps least bit, 6.5microsec range, single hit, incl. incl. PC-I/O-Card for ISA-Bus + all connection cables from DLATR6 to PC + CoboldPC data acquisition and analysing software. Yields 100 micron position resolution if used with DLD 40 and 80 micron with DLD 80.

HM1/T: 4-channel TDC 5-20 kHz data acquisition rate in single event list mode acquisition, 130ps least bit, 6.5microsec range, 3-fold multi hit, incl. PC-I/O-Card for ISA-Bus + ECL-TTL-Converter (8channels) + all connection cables from DLATR6 to PC + CoboldPC data acquisition and analysing software. Yields 100 micron position resolution if used with DLD 40 and 80 micron with DLD 80.

TDC-E1: 8-channel TDC 1-20 kHz data acquisition rate in single event list mode acquisition, 500ps least bit, 32 microsec range, 16-fold multi hit, pulse pair resolution 10-20ns, NIM-input, ISA-Bus + CoboldPC data acquisition and analysing software. Yields 500 micron position resolution if used with DLD 40 and 300 micron with DLD 80.

HV2/4: protective 2x4kV-high-voltage-power-supply for MCPs

CoboldPC: comfortable and powerful data-acquisition and analyzing software for multiparameter experiments, online and offline analysis, for Windows NT (Windows 95/98 possible but not recommended)

BA1: Voltage-supply set for delay line detectors. Provides floating 20V voltage difference (saves a power supply)

FT12-100: Mounting unit for DLD 40 incl. 12-pin-ceramics-UHV-feedthrough on CF35-norm + CF100-CF35-adapter for direct mounting of DLD 40 + UHV-cables for delay line detector fit to customer needs + connection cable from the flange to the DLATR6-module with high quality high voltage sockets certified up to 5kV.

FT12-150: Mounting unit for DLD80, same as FT12-100 but incl. CF150-CF35 adapter flange.

CC1: CAMAC-controller incl. CoboldPC for readout of most CAMAC modules (e.g. Ortec ADC, LeCroy/Ortec/Phillips TDC, others possible, software adapted to customers needs)

Back to the top

Flange mounted UHV detectors

All Fast Position- and Time-Sensitive MCP-Detectors listed above can be mounted on the standard CF flanges.

In addition, list of ready made Flange Mounted Detectors include classical Chevron type detectors with inexpensive image-quality MCPs and a metal or luminescence screen anode:

Detectors with Metal Anode FM-MA

FM-MA 24/2: Detector incl. 2 microchannel plates (MCP 24-10E, 0.48mm thick, 24mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 22mm, quality linear diameter is 20mm.  Metal anode.

FM-MA 34/2: Detector incl. 2 microchannel plates (MCP 34-10, 0.5mm thick, 34mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 32mm, quality linear diameter is 30mm.  Metal anode.

FM-MA 34/3: same as FM-MA 34/2, but incl. 3MCP for Z-stack

Vacuum Detectors with Phosphor Screen = Open Image Intensifiers

FM-GPS 24/2: Detector incl. 2 microchannel plates (MCP 24-10E, 0.48mm thick, 24mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 22mm, quality linear diameter is 20mm.  Luminescent screen anode.

FM-GPS 34/2: Detector incl. 2 microchannel plates (MCP 34-10, 0.5mm thick, 34mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 32mm, quality linear diameter is 30mm.  Luminescent screen anode.

FM-GPsS 34/3: same as FM-LS 34/2, but incl. 3MCP for Z-stack

Back to the top

Image Intensifiers

 

DelMar Ventures Home

MCP Main 

List of products

Worldwide Distributors

Del Mar Ventures
12595 Ruette Alliante #148
San Diego, CA 92130

v/fax: (509) 752-0123
delmarventures@yahoo.com
eyemail.gif (2917 bytes)
Join our mailing list!
You'll receive research and development news, information about new products, sales events and job opportunities.
Enter your email address below, then click the 'Join List' button:
Powered by ListBot

Copyright © 1999, 2000 [Del Mar Ventures]. All rights reserved.