DLD 40/2: 2-dim Delay-Line-Detector incl. 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%, Multihit proved) for Chevron configuration. Active diameter of the detector is 48mm, quality linear diameter is 44mm. Detector size: diameter 94mm, height 30mm. Maximum count rate of the anode is 1MHz.
DLD 40/3: same as DLD 40/2, but incl. 3MCP for Z-stack
DLD 40/P: 2-dim Delay-Line-Detector incl. 2 Photonis microchannel plates imaging quality (MCP 80:1, 1mm thick, 46mm outer diameter, matched in resistance within 10%, Multihit proved) for Chevron configuration. Active diameter of the detector is 44mm, quality linear diameter is 43mm. Detector size: diameter 94mm, height 30mm. Maximum count rate of the anode is 1MHz.
DLD 80/2: 2-dim Delay-Line-Detector incl. 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 86mm outer diameter, matched in resistance within 10% multi hit proved) for Chevron configuration. Active diameter of the detector is 83mm, quality linear diameter is 79mm. Detector size: diameter 144mm, height 30mm. Maximum count rate of the anode is 1MHz.
DLD 80/3: same as DLD 80/2, but incl. 3 MCP for Z-stack. Height is 30mm
DLD 100/2: 2-dim Delay-Line-Detector incl. Phillips microchannel plates (MCP Phillips 80:1, 1mm thick, 100mm outer measure, square, matched in resistance within 20%) for Chevron configuration. Active size 96mm square, quality area 93mm square. Maximum count rate of the anode is 1MHz.
WSD 40/2: 2-dim Wedge-and-Strip-Detector incl 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 48mm, quality linear diameter is 46mm. Detector size: diameter 66mm, height 7.5mm. Maximum count rate of the anode is 20kHz.
WSD 40/3: same as WSD 40/2, but incl. 3 MCP for Z-stack
RAD 40/2: 1-dim Resistive-Anode-Detector incl 2 Galileo long life microchannel plates (MCP 60:1, 1.5mm thick, 50mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active length of the detector is 48mm, quality linear length is 40mm. Active width can be chosen between 5 and 25mm. Detector size: diameter 66mm, height 7.5mm.
RAD 40/3: same as RAD 40/2, but incl. 3 MCP. Height is 8.5mm
DLATR6/N: triple width NIM-module differential amplifier constant fraction-unit all 6 channels for use with any DLD. Output NIM. For custom connection to vacuum system.
DLATR6/E: triple width NIM-module differential amplifier constant fraction-unit all 6 channels for use with any DLD. Output ECL incl. integrated 2-channel ECL-TTL converter for monitoring. For custom connection to vacuum system.
CATSA2: preamplifier box incl. 2 slow high end charge integrating preamps for very good signal-to-noise ratio (200nanosec or 1microsec fall time). Amplification optimized for use with RAD 40. Achievable position resolution with RAD 40 is 100 micron.
CATSA3: preamplifier box incl. 3 slow high end charge integrating preamps for very good signal-to-noise ratio (200nanosec or 1microsec fall time). Amplification optimized for use with WSD 40. Achievable position resolution with WSD 40 is 50 micron.
HM1: 4-channel histogramming TDC with 32MB memory on board for 0.5-1 MHz data acquisition rate, 130ps least bit, 6.5microsec range, single hit, incl. incl. PC-I/O-Card for ISA-Bus + all connection cables from DLATR6 to PC + CoboldPC data acquisition and analysing software. Yields 100 micron position resolution if used with DLD 40 and 80 micron with DLD 80.
HM1/T: 4-channel TDC 5-20 kHz data acquisition rate in single event list mode acquisition, 130ps least bit, 6.5microsec range, 3-fold multi hit, incl. PC-I/O-Card for ISA-Bus + ECL-TTL-Converter (8channels) + all connection cables from DLATR6 to PC + CoboldPC data acquisition and analysing software. Yields 100 micron position resolution if used with DLD 40 and 80 micron with DLD 80.
TDC-E1: 8-channel TDC 1-20 kHz data acquisition rate in single event list mode acquisition, 500ps least bit, 32 microsec range, 16-fold multi hit, pulse pair resolution 10-20ns, NIM-input, ISA-Bus + CoboldPC data acquisition and analysing software. Yields 500 micron position resolution if used with DLD 40 and 300 micron with DLD 80.
HV2/4: protective 2x4kV-high-voltage-power-supply for MCPs
CoboldPC: comfortable and powerful data-acquisition and analyzing software for multiparameter experiments, online and offline analysis, for Windows NT (Windows 95/98 possible but not recommended)
BA1: Voltage-supply set for delay line detectors. Provides floating 20V voltage difference (saves a power supply)
FT12-100: Mounting unit for DLD 40 incl. 12-pin-ceramics-UHV-feedthrough on CF35-norm + CF100-CF35-adapter for direct mounting of DLD 40 + UHV-cables for delay line detector fit to customer needs + connection cable from the flange to the DLATR6-module with high quality high voltage sockets certified up to 5kV.
FT12-150: Mounting unit for DLD80, same as FT12-100 but incl. CF150-CF35 adapter flange.
CC1: CAMAC-controller incl. CoboldPC for readout of most CAMAC modules (e.g. Ortec ADC, LeCroy/Ortec/Phillips TDC, others possible, software adapted to customers needs)
All Fast Position- and Time-Sensitive MCP-Detectors listed above can be mounted on the standard CF flanges.
In addition, list of ready made Flange Mounted Detectors include classical Chevron type detectors with inexpensive image-quality MCPs and a metal or luminescence screen anode:
Detectors with Metal Anode FM-MA
FM-MA 24/2: Detector incl. 2 microchannel plates (MCP 24-10E, 0.48mm thick, 24mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 22mm, quality linear diameter is 20mm. Metal anode.
FM-MA 34/2: Detector incl. 2 microchannel plates (MCP 34-10, 0.5mm thick, 34mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 32mm, quality linear diameter is 30mm. Metal anode.
FM-MA 34/3: same as FM-MA 34/2, but incl. 3MCP for Z-stack
Vacuum Detectors with Phosphor Screen = Open Image Intensifiers
FM-GPS 24/2: Detector incl. 2 microchannel plates (MCP 24-10E, 0.48mm thick, 24mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 22mm, quality linear diameter is 20mm. Luminescent screen anode.
FM-GPS 34/2: Detector incl. 2 microchannel plates (MCP 34-10, 0.5mm thick, 34mm outer diameter, matched in resistance within 10%) for Chevron configuration. Active diameter of the detector is 32mm, quality linear diameter is 30mm. Luminescent screen anode.
FM-GPsS 34/3: same as FM-LS 34/2, but incl. 3MCP for Z-stack