Specifications:

Gd-doped luminescent screen made of powder luminophore (Gd2O2S: Tb) for thermal neutrons and
composite material consisting of an organic resin and a powder luminophore (Gd2O2S: Tb) for fast neutrons

Sensitive area diam. 30 - 350mm, other sizes available on request

CCD matrix 1000x1000 cooled by two-stage peltier (thermoelectric) cooler

Ultimate spatial resolution up to 30mm for thermal neutrons, about 1mm for fast neutrons

Detection efficiency - for thermal neutrons ~ 60%
                                2.5MeV neutrons (D-D reaction) ~ 1%
                                14MeV neutrons (D-T reaction) ~ 0.25%

Dynamic range - 14 bit

Detector size (for diam.150mm screen) ~ 400x400x1000mm

The complete NID2000 system comprises a luminescence screen, MCP intensified CCD camera, camera controller, PCI interface card and software running under Windows™.
We supply Basic software package NI2 as well as Tomographic Reconstruction Software NT3.

Neutron Imaging Detectors Installed Worldwide

Applications:

Medical Diagnostics
Imaging of neutron and
g-ray fields in Neutron Capture Therapy and Neutron Beam Therapy
Control of the spatial distribution stability of neutron fluxes in medical applications
Detection of boron and gadolinium in neutron-capturing therapy.
Recognition of cancers, tumors, etc.

Neutron radiography and tomography systems
Inspection of components of  electronic products, airplanes, rockets, automobiles, alloys, etc.
Non-destructive inspection for civil engineering, aviation, etc.

Neutron Crystallography
3D Structural analysis of polymers, protein, etc.
Neutron diffraction analysis of superconducting material, etc.

Neutron Checking & Monitoring
Inspection of nuclear reactors, nuclear power plants, etc.

Art
Inspection of antiquities, paintings and sculpture, etc.
Verification of authenticity, identification of forgeries.

Neutron Position-Sensitive (Imaging) Detector can be used with all types of neutron sources:
Portable Neutron Generators, Nuclear Reactor, Accelerator, Radioisotope

General Description of MCP-based Imaging Detectors

Del Mar Ventures> Product List> Neutron Products Index>

Del Mar Ventures
4119 Twilight Ridge
San Diego, CA 92130
tel (858) 755-6727
fax (858) 755-6771
v/efax (858) 630-237
v/efax: (509) 752-0123
delmar@sciner.com
http://www.sciner.com/
http://www.femtosecondsystems.com/

eyemail.gif (2917 bytes)